UNITHERM
UNITHERM is identified as a microreactor design in the ARIS status report dated 2024-10-16, attributed to NIKIET. This dated design identity does not establish current availability, a deployment site, output, or regulatory permission. The IAEA's 2026 catalog section, supplied by its contributor, calls it an integral type reactor and lists the type as PWR. Other technical values remain unknown here pending an independent scope and basis check.
- Reactor type
- Integral pressurized water reactor. How it works, with a 3D view.
- Projects
- No projects tracked here. Development status as stated in the catalog dated 16 Oct 2024: Conceptual design.
- Evidence
- 3 sources; first primary source: ARIS original status report — UNITHERM (2024-10-16). Record reviewed 2 Oct 2026.
Key facts · Tracked projects · Sources · Evidence · Compare with other designs
Catalog identity snapshot: 16 Oct 2024 (ARIS report publication). Later technical descriptions, where recorded, are dated separately below. Source review does not establish current availability or a deployment.
Key facts
- Class
- Microreactor
- Technology
- Integral pressurized water reactor (iPWR)
The IAEA's 2026 catalog section, supplied by its contributor, calls UNITHERM an integral type reactor with its nuclear steam supply system equipment inside the reactor pressure vessel, and lists the type as PWR. - Coolant
- Light water
- Spectrum
- Thermal
- Developer / vendor(s) as of 16 Oct 2024
- NIKIET
- Fuel form
- UO2 particles in a metallic silumin or zirconium matrix, metal-ceramic
- Development status (as stated)
- Conceptual design
- Reactor vessel
- 9.8 m tall, 2.9 m across. Developer's figure in the IAEA ARIS catalog, 2026 edition, printed p. 487.
SMRMap has not checked this against drawings or regulators' documents. A larger vessel does not mean a more powerful reactor, and a reactor vessel is not a whole power plant. The catalog has no open license. These figures are quoted from it and are not offered under SMRMap's CC BY 4.0 data license. These vessel figures are page reference material, outside SMRMap's downloadable dataset and its dataset fingerprint. Quoted source material retains its separate rights.All vessels to scale10 m bar; a person 1.8 m tallUNITHERM
9.8 m tall, 2.9 m across - Inclusion basis
- Labeled microreactor
- Confidence
- medium
- Not yet recorded
- Expected but not recorded as a structured fact: Module rating (reviewed: not disclosed in the reviewed evidence; see Evidence and open questions). A missing structured fact does not mean zero or that it does not exist; a documented review limit is named beside the fact, and the description and sources may say more.
- Record reviewed
- 2 Oct 2026 (record review date, not proof of current availability or a deployment)
All fields
(2 without a known value)
- Module electrical
- Not recorded
- Module thermal
- Not recorded
Tracked deployment projects
- No projects tracked here.
Design sources
(3)
- ARIS original status report — UNITHERM (2024-10-16) (IAEA/NEA, accessed 2 Oct 2026)
- Small Modular Reactor Technology Catalogue, 2024 edition (contributor material; June 2025 third edition) (IAEA/NEA, published Jun 2025, accessed 2 Oct 2026)
- Small Modular Reactor Technology Catalogue, 2026 edition (contributor material; printed September 2026) (IAEA/NEA, published Sep 2026, accessed 2 Nov 2026)
Evidence and open questions
(3 notes)
- Evidence review. The ARIS report identifies UNITHERM for the Russian Federation and classifies design status as conceptual design. A sentence that does not contain a rating says the reactor is intended to supply electricity to urban areas and industrial enterprises in remote regions. The catalog summary names Unitherm, a PWR, NIKIET, conceptual design. Its numeral has no unit and is not stored. ARIS output figures are not copied. Stored conceptual-design status matches. The family is iPWR because the 2026 catalog section, attached for the reactor type only, places the nuclear steam supply system equipment inside the reactor pressure vessel. Last checked 19 Oct 2026. ARIS original status report — UNITHERM (2024-10-16); Small Modular Reactor Technology Catalogue, 2024 edition (contributor material; June 2025 third edition)
What would change this
A NIKIET specification, outside ARIS, that states electrical and thermal output with a basis. Next scheduled check: 19 Jan 2027.
- Module rating: Not disclosed in the reviewed evidence. No unit-qualified rating is adopted. This identity profile stores no module output. Last checked 19 Oct 2026. ARIS original status report — UNITHERM (2024-10-16); Small Modular Reactor Technology Catalogue, 2024 edition (contributor material; June 2025 third edition)
What would change this
A non-ARIS NIKIET datasheet with UNITHERM MWe and MWth. Next scheduled check: 19 Jan 2027.
- Technology family. The IAEA's 2026 catalog section, supplied by its contributor, calls UNITHERM an integral type reactor with its nuclear steam supply system equipment inside the reactor pressure vessel, and lists the type as PWR. Its steam generating modules sit on the reactor cover. Printed pages 487 and 489. Last checked 3 Nov 2026. Small Modular Reactor Technology Catalogue, 2026 edition (contributor material; printed September 2026)
What would change this
A NIKIET or IAEA document that changes the UNITHERM reactor type or layout. Next scheduled check: 3 Feb 2027.