Thorcon 500 (TMSR500)
BAPETEN describes a 500 MWe molten-salt plant. WNN, citing Thorcon, describes two 250 MWe reactors in sealed cans. Gross versus net is not stated. Site-evaluation approval is not a construction license. Plant total is 500 MWe, above the per-module guide; inclusion uses the stated 250 MWe module.
- Reactor type
- Molten salt reactor. How it works, with a 3D view.
- Projects
- Siting: Thorcon 500, Kelasa Island. Development status as stated: Preliminary design.
- Evidence
- 4 sources; first primary source: BAPETEN receipt of Thorcon TMSR500 site-evaluation application. Record reviewed 1 Oct 2026.
Key facts · Tracked projects · Sources · Evidence · Regulatory actions · Its projects in the table · Compare with other designs
Key facts
- Class
- SMR
- Technology
- Molten salt reactor (MSR)
- Coolant
- Molten salt
- Spectrum
- Thermal
- Developer / vendor(s)
- PT Thorcon Power Indonesia
- Module electrical
- 250 MWe (gross/net unspecified)
- Fuel form
- UF4 / molten salt
- Development status (as stated)
- Preliminary design
- Inclusion basis
- Vendor SMR claim, capacity checked
- Confidence
- medium
- Record reviewed
- 1 Oct 2026 (record review date, not proof of current availability or a deployment)
All fields
(1 without a known value)
- Module thermal
- Not recorded
Tracked deployment projects
- Thorcon 500, Kelasa Island — Siting · Indonesia
Design sources
(4)
- BAPETEN receipt of Thorcon TMSR500 site-evaluation application (regulator, accessed 1 Oct 2026)
- WNN: regulatory approval for Indonesian Thorcon site survey (news report, accessed 1 Oct 2026)
- BAPETEN site-evaluation approval, Thorcon 500, Kelasa (regulator, accessed 1 Oct 2026)
- Small Modular Reactor Technology Catalogue, 2024 edition (contributor material; June 2025 third edition) (IAEA/NEA, published Jun 2025, accessed 2 Oct 2026)
Evidence and open questions
(1 note)
- Evidence review. The June 2025 IAEA catalog section contributed by Thorcon International calls Thorcon a thermal molten salt reactor, with molten salt coolant and graphite moderator, and lists thermal/electrical capacity as 557 / 250 (per module). Design status in that section is preliminary design. The same section says each 250 MWe power module contains two replaceable reactors in sealed cans, and another sentence says 557 MWe reactor cans, which does not match the table's placement of 557 in the MWt position. World Nuclear News on 5 August 2025, citing the project, describes a 500 MWe plant of two 250 MWe reactors in sealed cans. BAPETEN's page records evaluation of PT Thorcon Power Indonesia's site-evaluation application for the Thorcon 500 plant at Kelasa Island, filed 21 January 2025. That is a site-evaluation step, not a construction license. Stored 250 MWe per module agrees with the catalog's per-module electrical figure and with WNN. The thermal number is not stored because the catalog section uses 557 both as MWt in the table and as MWe in one sentence. Last checked 19 Oct 2026. Small Modular Reactor Technology Catalogue, 2024 edition (contributor material; June 2025 third edition); WNN: regulatory approval for Indonesian Thorcon site survey; BAPETEN site-evaluation approval, Thorcon 500, Kelasa
What would change this
A Thorcon or BAPETEN design approval that resolves whether 557 is MWt per module and whether 250 MWe is per can or per power module. Next scheduled check: 19 Jan 2027.
Regulatory actions
Compare reviews and approvals across designs
Site applications and decisions
- BAPETEN Kelasa site-evaluation approval — Thorcon 500, Kelasa Island
Site permission · Issued / approved · BAPETEN · decided 30 Jul 2025
Decision 00003.556.1.300725 authorizes PT Thorcon Power Indonesia to conduct site evaluation under its PET and SMET. It is not a construction license.
Sources: BAPETEN site-evaluation approval, Thorcon 500, Kelasa; BAPETEN safety-evaluation report index, Thorcon 500