How small reactor types work · Design list

How a heat-pipe microreactor works

eVinci is a heat-pipe microreactor: it has no bulk primary coolant, that is, no body of liquid or gas flowing through the core, and sealed heat pipes holding sodium carry heat from the core to a heat exchanger.[1, pp. 413, 414, 415]

This page explains the type on one documented design, simplified; other designs of the type can differ. It describes the design, not a project: see the eVinci record. SMRMap tracks 5 projects using it, and each project's record carries its status.

eVinci heat-pipe microreactor, simplified side section with numbered partsA horizontal canister holds a graphite core block with rows of fuel compacts, with control drums above and below it and shutdown rods coming in from the left. Heat pipes run from the block to the right, through a shield, into a heat exchanger. Solid arrows along the pipes point right. One dashed arrow drawn just below one pipe points left and shows liquid coming back inside that pipe. Below the exchanger, a single arrow shows heat transfer to a power conversion block. The open-air cycle's air intake and exhaust are not drawn.12345678Heat taken upHeat given upOpen-air Brayton cycle
Simplified from the IAEA SMR Technology Catalogue 2026, eVinci section (printed pages 413–417). Parts and proportions not stated in the source are schematic. The section gives no dimensions, so nothing here is to scale. The order of the parts along the axis follows the catalog's drawing on printed page 415. The numbers of pipes, compacts, drums and rods are schematic, the six-sided block is drawn as a plain block, and the shapes around the block and between it and the exchanger, which the drawing labels radial reflector and shielding, are left unlabeled. The rods are drawn in line with pipes only because everything lies on one cut; in the catalog's drawing they enter the block in their own positions. The power conversion block sits below the exchanger only to keep the figure compact; the catalog's picture on printed page 413 shows the Brayton unit at the end of the canister in the same container. Numbers match the sections below; arrows show the heat path.
  • Heat moving along the sealed pipes, as the section's text gives
  • Liquid coming back inside a pipe, drawn just below it: from the catalog's generic picture of a heat pipe, not its text
  • Heat transferred to the open-air power conversion system; air intake, internal routing and exhaust are not drawn

The parts, numbered as in the figure

1. Reactor canister

A canister encases the whole core; the section's containment part calls it the canister containment subsystem and says it is designed to contain the fuel and fission products.[1, p. 416] The table gives no vessel size or weight, so this drawing has no stated dimensions.[1, p. 413]

2. Graphite core block

The core is a single six-sided block of graphite with a pattern of channels through it, for heat pipes and fuel compacts.[1, p. 415] Graphite is also the moderator, the material that slows the neutrons so the fuel can keep a chain reaction going.[1, p. 413]

3. TRISO fuel compacts

The fuel is TRISO, tiny coated grains of uranium fuel, enriched to 19.75% and arranged in compacts that sit in the block's channels.[1, pp. 415, 417] The section says the core can run 8 or more years at full power without refueling, and refueling is not done on the customer's site.[1, p. 417]

4. Sodium heat pipes

The pipes sit in channels in the core, and each one is fully enclosed, with sodium inside.[1, pp. 414, 415] Capillary forces, the wicking that pulls water up a paper towel, and pressure differences move the heat from one end of the pipe to the other, with no coolant pump in the primary system.[1, pp. 414, 415] The catalog's generic picture of a heat pipe shows vapor moving to the cool end and liquid coming back along a wick.[1, p. 414]

5. Control drums

Radial drums around the core adjust the reactor's power, which is reactivity control, and shut it down. Separate shutdown rods can also enter the core.[1, p. 415]

6. Shutdown rods

Shutdown can also be done with rods that go into the core block.[1, p. 415] The catalog's drawing shows them coming in from one end of the canister, as the figure does.[1, p. 415]

7. Heat exchanger

The heat pipes carry the heat to this exchanger, which passes it to the power conversion system.[1, p. 415] The catalog's drawing labels it the primary heat exchanger and shows it at the far end of the pipes, past a section it labels shielding and bulkhead.[1, p. 415]

8. Power conversion system

It uses an open-air Brayton cycle, a gas turbine cycle that takes in outside air and exhausts it rather than recirculating one charge, to turn the heat into electricity.[1, p. 413] The section says the reactor and this system fit in one standard transport container, with the electronics and controls in a second.[1, p. 413]

The heat path

  1. Heat from the fuel goes into the heat pipes, which run through channels in the core.[1, pp. 413, 415]
  2. The sodium sealed in each pipe moves the heat along it, driven by capillary forces and pressure differences.[1, p. 414]
  3. At the far end the pipes give up the heat to the heat exchanger and on to the working fluid of the power conversion system, the gas that drives its turbine.[1, pp. 414, 415]
  4. An open-air Brayton cycle turns that heat into electricity.[1, p. 413]
  5. The section's text does not describe what happens inside a pipe in more detail, or how the working fluid moves through the power conversion system, and its table lists coolant temperatures as not applicable.[1, pp. 413–417]
  6. The dashed line in the pipes follows the catalog's generic picture of a heat pipe, which shows liquid returning along a wick. The separate arrow to power conversion shows heat transfer only; outside-air intake and exhaust are not drawn.[1, p. 414]

Where are the coolant and the coolant pumps?

The section says eVinci has no bulk primary coolant, and that with heat pipes its primary system needs no coolant pumps.[1, pp. 414, 415] This is eVinci. SMRMap lists a design here when its record describes a reactor whose heat leaves through heat pipes, and those designs can differ; the interactive view shows eVinci only. One listed record differs on that first point: NuScale's microreactor record describes a liquid moderator-coolant, with heat pipes as the heat-exchange interface to power conversion, so it does have a bulk coolant.

  • Coolant. The table's coolant entry is heat pipes with sodium, and the sodium stays sealed in each pipe.[1, pp. 413, 414]
  • Pumps. That statement is about the reactor's primary system, the heat pipes that take heat out of the core; the section does not say what moves air through the separate Brayton power conversion system.[1, pp. 413, 415]
  • HARPIA. Another heat-pipe design in the same catalog; its table also lists heat pipes as the coolant, with beryllium oxide and graphite as moderator.[1, p. 419]

Design values

These are values listed in the catalog section, which the developer supplied.[1, p. 413]

  • Power. 15 MW(t) of heat and 5 MW(e) of electricity.[1, p. 413]
  • Pressure. The table's pressure row lists 0.12 MPa for the primary side, a little above atmospheric pressure, and does not say whether that is inside the heat pipes or the canister.[1, p. 413]
  • Fuel. Enrichment 19.75%; the table gives a refueling cycle of 8 full-power years.[1, pp. 413, 417]
  • Size. The table lists no vessel dimensions and no core temperatures.[1, p. 413]

Designs on SMRMap recorded as this type

8 designs, with 9 tracked projects between them. Each design's type comes from its own record on SMRMap; the example above is one of them, and the others can differ from it.

DesignClassElectrical output Tracked projects
ELYON-5Microreactor5 MWe (gross/net unspecified) · moduleNone tracked here
eVinciMicroreactor5 MWe (gross/net unspecified) · module5
HARPIAMicroreactor—None tracked here
MoveluXMicroreactor—None tracked here
NuScale microreactorMicroreactor—None tracked here
NuSun-1Microreactor—1
R1Microreactor—3
ZiaCoreMicroreactor—None tracked here

Sources

  1. Small Modular Reactor Technology Catalogue, 2026 edition (contributor material; printed September 2026) — IAEA ARIS (catalog host; profiles supplied by contributors). eVinci section, printed pages 413–417; HARPIA section, printed page 419. Each section is contributor material; the eVinci section was supplied by Westinghouse Electric Company.